Dry adhesive mixtures based on cement binder

The result obtained indicates a large number of incorrectly answered questions. Read recommended articles on these issues.
You scored 0 out of 5 possible points.
Your result: 0%
Question 1

What requirements must be met for adhesive mortar mixtures (ready-to-use)?

Score: 0 out of 1
Your AnswerOptionRight?Result
Selected

The average density of adhesive mortar mixtures is set by the manufacturer at the request of the consumer

Correct
1
Selected

Resistance to slipping of adhesive mixtures is characterized by the value of displacement under the influence of gravity of facing tiles laid on a vertical or inclined surface. For adhesive mixtures, the offset value should be no more than 1.5 mm.

Incorrect
-1
Selected

The water-holding capacity of adhesive mortar mixtures, ready for use, must be at least 85%

Incorrect
-1
Selected

Resistance to slipping of adhesive mixtures is characterized by the value of displacement under the influence of gravity of facing tiles laid on a vertical or inclined surface. For adhesive mixtures of class T, the displacement value should be no more than 0.5 mm, for mixtures of other classes - no more than 0.7 mm.

Correct
1
Selected

The water-holding capacity of ready-to-use adhesive mortar mixtures must be at least 98%

Correct
1
Selected

The average density of adhesive mortar mixtures must exceed 1800 kg/m3

Incorrect
-1

Material on this issue is presented in the GOST R 56387 .

Question 2

An example of a symbol for an adhesive mixture based on a cement binder, intended for interior and exterior work, meeting increased requirements, with increased resistance to slipping, increased open time and high elasticity.

Score: 0 out of 1
Your AnswerOptionRight?Result

Dry construction adhesive mixture C1 FE S2, GOST R 56387

0
Selected

Dry construction adhesive mixture C2 TE S1, GOST R 56387

Incorrect
0

Dry construction adhesive mixture C1 TE S2, GOST R 56387

0

Dry construction adhesive mixture C2 FE S2, GOST R 56387

0

Dry construction adhesive mixture C1 TE S1, GOST R 56387

0

Dry construction adhesive mixture C2 TE S2, GOST R 56387

0

Material on this issue is presented in the GOST R 56387 .

Question 3

To mix (dilute, mix) cement adhesive mixtures of class C1, it is necessary to use...

Score: 0 out of 1
Your AnswerOptionRight?Result

Synthetic oil

0

PVA - emulsion of polyvinyl acetate in water, with a plasticizer and special additives

0
Selected

Adhesive milk

Incorrect
-1
Selected

Water-based latex mixture

Correct
1
Selected

Primer

Incorrect
-1

Water latex

0

Water

0
Selected

Vegetable oil

Incorrect
-1

Material on this issue is presented in technical data sheets for cement adhesive mixtures.

Question 4

The symbol of adhesive mixtures must consist of the name of the mixture in accordance with GOST 31189, class designation, values ​​of basic quality indicators (if necessary) and standard designation. Adhesive mixtures are divided into the following classes...

Score: 0 out of 1
Your AnswerOptionRight?Result

F – mixtures with extended open time

0

S2− elastic adhesive mixtures

0

T – quick-hardening adhesive mixtures

0

S1 – highly elastic mixtures

0

C0 – used for laying tiles with normal water absorption (at least 5% by weight) only for interior work

0
Selected

C1 – used for interior and exterior work and meeting the minimum regulated requirements

Correct
1

C2 - used for interior and exterior work and meeting increased requirements

0

E – mixtures with increased resistance to slipping

0

Material on this issue is presented in the GOST R 56387 .

Question 5

Adhesive mixtures must comply with the requirements of the GOST R 56387 standard and be manufactured according to technological documentation approved by the manufacturer. The main indicators of the quality of adhesive mixtures ready for use (freshly prepared) are ...

Score: 0 out of 1
Your AnswerOptionRight?Result
Selected

Open time

Incorrect
-1
Selected

Resistance to slippage

Correct
1
Selected

Maximum Density

Incorrect
-1
Selected

Humidity

Incorrect
-1
Selected

Minimum Density

Incorrect
-1
Selected

Water holding capacity

Correct
1
Selected

Average density

Correct
1

Material on this issue is presented in the GOST R 56387 .

For any suggestions regarding the site: [email protected]
Для любых предложений по сайту: [email protected]